Category: HPC

Key Components for Setting Up an HPC Cluster

Head Node (Controller)

 Manages job scheduling and resource allocation.
 Runs Slurm Controller Daemon (`slurmctld`).

Compute Nodes

 Execute computational tasks.
 Run Slurm Node Daemon (`slurmd`).
 Configured for CPUs, GPUs, or specialized hardware.

Networking

 High-speed interconnect like Infiniband or Ethernet.
 Ensures fast communication between nodes.

Storage

 Centralized storage like NFS, Lustre, or BeeGFS.
 Provides shared file access for all nodes.

Authentication

 Use Munge for secure communication between Slurm components.

Scheduler

 Slurm for job scheduling and resource management.
 Configured with partitions and node definitions.

Resource Management

 Use cgroups to control CPU, memory, and GPU usage.
 Optional: ProctrackType=cgroup in Slurm.

Parallel File System (Optional)

 High-performance shared storage for parallel workloads.
 Examples: Lustre, GPFS.

Interconnect Libraries

 MPI (Message Passing Interface) for distributed computing.
 Install libraries like OpenMPI or MPICH.

Monitoring and Debugging Tools

 Tools like Prometheus, Grafana, or Ganglia for resource monitoring.
 Enable verbose logging in Slurm for debugging.

How to configure Slurm Controller Node on Ubuntu 22.04

How to setup HPC-Slurm Controller Node

Refer to Key Components for HPC Cluster Setup; for which pieces you need to setup.

This guide provides step-by-step instructions for setting up the Slurm controller daemon (`slurmctld`) on Ubuntu 22.04. It also includes common errors encountered during the setup process and how to resolve them.

Step 1: Install Prerequisites

To begin, install the required dependencies for Slurm and its components:

sudo apt update && sudo apt upgrade -y
sudo apt install -y munge libmunge-dev libmunge2 build-essential man-db mariadb-server mariadb-client libmariadb-dev python3 python3-pip chrony

Step 2: Configure Munge (Authentication for slurm)

Munge is required for authentication within the Slurm cluster.

1. Generate a Munge key on the controller node:
sudo create-munge-key

2. Copy the key to all compute nodes:
scp /etc/munge/munge.key user@node:/etc/munge/

3. Start the Munge service:
sudo systemctl enable –now munge

Step 3: Install Slurm

1. Download and compile Slurm:
wget https://download.schedmd.com/slurm/slurm-23.02.4.tar.bz2
tar -xvjf slurm-23.02.4.tar.bz2
cd slurm-23.02.4
./configure –prefix=/usr/local/slurm –sysconfdir=/etc/slurm
make -j$(nproc)
sudo make install

2. Create necessary directories and set permissions:
sudo mkdir -p /etc/slurm /var/spool/slurm /var/log/slurm
sudo chown slurm: /var/spool/slurm /var/log/slurm

3. Add the Slurm user:
sudo useradd -m slurm

Step 4: Configure Slurm; more complex configs contact Nick Tailor

1. Generate a basic `slurm.conf` using the configurator tool at
https://slurm.schedmd.com/configurator.html. Save the configuration to `/etc/slurm/slurm.conf`.

# Basic Slurm Configuration

ClusterName=my_cluster

ControlMachine=slurmctld # Replace with your control node’s hostname

# BackupController=backup-slurmctld # Uncomment and replace if you have a backup controller

.

# Authentication

AuthType=auth/munge

CryptoType=crypto/munge

.

# Logging

SlurmdLogFile=/var/log/slurm/slurmd.log

SlurmctldLogFile=/var/log/slurm/slurmctld.log

SlurmctldDebug=info

SlurmdDebug=info

.

# Slurm User

SlurmUser=slurm

StateSaveLocation=/var/spool/slurm

SlurmdSpoolDir=/var/spool/slurmd

.

# Scheduler

SchedulerType=sched/backfill

SchedulerParameters=bf_continue

.

# Accounting

AccountingStorageType=accounting_storage/none

JobAcctGatherType=jobacct_gather/linux

.

# Compute Nodes

NodeName=node[1-2] CPUs=4 RealMemory=8192 State=UNKNOWN

PartitionName=debug Nodes=node[1-2] Default=YES MaxTime=INFINITE State=UP

2. Distribute `slurm.conf` to all compute nodes:
scp /etc/slurm/slurm.conf user@node:/etc/slurm/

3. Restart Slurm services:
sudo systemctl restart slurmctld
sudo systemctl restart slurmd

Troubleshooting Common Errors

.

root@slrmcltd:~# tail /var/log/slurm/slurmctld.log

[2024-12-06T11:57:25.428] error: High latency for 1000 calls to gettimeofday(): 20012 microseconds

[2024-12-06T11:57:25.431] fatal: mkdir(/var/spool/slurm): Permission denied

[2024-12-06T11:58:34.862] error: High latency for 1000 calls to gettimeofday(): 20029 microseconds

[2024-12-06T11:58:34.864] fatal: mkdir(/var/spool/slurm): Permission denied

[2024-12-06T11:59:38.843] error: High latency for 1000 calls to gettimeofday(): 18842 microseconds

[2024-12-06T11:59:38.847] fatal: mkdir(/var/spool/slurm): Permission denied

Error: Permission Denied for /var/spool/slurm

This error occurs when the `slurm` user does not have the correct permissions to access the directory.

Fix:
sudo mkdir -p /var/spool/slurm
sudo chown -R slurm: /var/spool/slurm
sudo chmod -R 755 /var/spool/slurm

Error: Temporary Failure in Name Resolution

Slurm could not resolve the hostname `slurmctld`. This can be fixed by updating `/etc/hosts`:

1. Edit `/etc/hosts` and add the following:
127.0.0.1
slurmctld
192.168.20.8
slurmctld

2. Verify the hostname matches `ControlMachine` in `/etc/slurm/slurm.conf`.

3. Restart networking and test hostname resolution:
sudo systemctl restart systemd-networkd
ping slurmctld

Error: High Latency for gettimeofday()

Dec 06 11:57:25 slrmcltd.home systemd[1]: Started Slurm controller daemon.

Dec 06 11:57:25 slrmcltd.home slurmctld[2619]: slurmctld: error: High latency for 1000 calls to gettimeofday(): 20012 microseconds

Dec 06 11:57:25 slrmcltd.home systemd[1]: slurmctld.service: Main process exited, code=exited, status=1/FAILURE

Dec 06 11:57:25 slrmcltd.home systemd[1]: slurmctld.service: Failed with result ‘exit-code’.

This warning typically indicates timing issues in the system.

Fixes:
1. Install and configure `
chrony` for time synchronization:
sudo apt install chrony
sudo systemctl enable –now chrony
   chronyc tracking
timedatectl
2. For virtualized environments, optimize the clocksource:
sudo echo tsc > /sys/devices/system/clocksource/clocksource0/current_clocksource

3. Disable high-precision timing in `slurm.conf` (optional):
HighPrecisionTimer=NO
sudo systemctl restart slurmctld

Step 5: Verify and Test the Setup

1. Validate the configuration:
scontrol reconfigure
– no errors mean its working. If this doesn’t work check the connection between nodes
update your /etc/hosts to have the hosts all listed across the all machines and nodes.

2. Check node and partition status:
sinfo

root@slrmcltd:/etc/slurm# sinfo

PARTITION AVAIL TIMELIMIT NODES STATE NODELIST

debug* up infinite 1 idle* node1

3. Monitor logs for errors:
sudo tail -f /var/log/slurm/slurmctld.log

.

Written By: Nick Tailor